Combination
- Products
- >
- Custom Install
- >
- Combination
- >
- Product Detail
- Two CAT6 + two RG6QSC in overall jacket configuration
- TV + Auxiliary video + Phone + Data
- CAT6 is rated 550MHz with rip cord
- RG6QSC is solid copper and rated 3.0GHz
- UL® CMR, CSA FT4 RoHS
- Available in violet 500’ spools
|
Element 1 (CAT6) Conductor |
||||
|
Total Number of Conductors |
4 pairs of 8 / 23 AWG |
|||
|
Construction |
1/23 AWG |
|||
|
Diameter |
0.0201” (Approx.) |
|||
|
Conductor Material |
Solid Bare Copper |
|||
|
Insulation |
||||
|
Insulation Material |
HDPE – High Density PE |
|||
|
Overall Diameter |
0.035 in. ± 0.001 in. |
|||
|
Average Thickness |
0.008 in. |
|||
|
Pair Color Code Chart |
||||
|
Number |
Color |
Number |
Color |
|
|
1 |
Blue &White/Blue Stripe |
3 |
Green & White/Green Stripe |
|
|
2 |
Orange &White/Orange Stripe |
4 |
Brown & White/Brown Stripe |
|
Mechanical Characteristics
|
Jacket |
(100 ± 1.0°C x 240 H) |
Before Aging |
After Aging |
|
|
Tensile Strength (M |
>=13.8 |
>=85% Unaged minimum |
|
Elongation |
>=100% |
>=50% Unaged minimum |
|
Rated Temperature/Voltage |
75°C (167°F) / 300V |
|
|
Cold Bend Test |
No Crack (-20°C ± 1°C x 4 H) |
|
|
Electrical Characteristics |
||
|
Voltage – Withstand Test |
1.5 kV AC min of 2 seconds (Insulation) 0.85 kV AC min of 2 seconds (Jacket) |
|
|
Spark Test |
1.75 kV AC/2s |
|
|
Dielectric Strength |
AC 1.5 kV/min |
|
|
AC Leakage Current through Overall Jacket |
AC 1500V≤10mA |
|
|
Mutual Capacitance |
56 pF/M max |
|
|
Maximum Conductor DC Resistance @ 20°C (68°F) |
93.8 Ohms/km |
|
|
Maximum DC Resistance Unbalanced @ 20°C (68°F) |
5% |
|
|
Maximum Pair-To-Pair Ground Capacitance Unbalanced |
330 pF/100m |
|
|
Characteristic Impedance (1~350 MHz) |
100 ± 15 Ohms |
|
|
Structural Return Loss @ 350 MHz |
8.2 dB Min. |
|
|
Maximum Propagation Delay @ 350 MHz |
536nS/100m |
|
|
Maximum Delay Skew (1~350 MHz) |
40nS/100m |
|
|
Maximum Operating Voltage – UL |
300 V RMS |
|
|
Insulation Shrink Back @ 150m/m |
121°C ± 1°C x 1HR≤9.5mm |
|
|
Element 2 (RG6QSC) Conductor |
||||
|
Composition |
18 AWG, 0.40” (Approx.) |
|||
|
Conductor Material |
Solid Bare Copper |
|||
|
Insulation |
||||
|
Insulation Material |
Foamed Polyethylene |
|||
|
Nominal Diameter |
1.80 ± 0.008” |
|||
|
Wall Thickness |
0.070” |
|||
|
Shielding |
||||
|
Layer |
Type |
Material |
% Coverage |
|
|
1 |
Tape |
Bonded Aluminum Mylar |
100% |
|
|
2 |
Braid |
16/5/0.12 Aluminum Wire |
60% |
|
|
3 |
Tape |
Aluminum Mylar |
100% |
|
|
4 |
Braid |
16/3/0.12 Aluminum Wire |
40% |
|
|
Electrical Characteristics |
||||
|
Impedance |
75 ± 5 Ohms |
|||
|
Capacitance |
16.2 pF/ft |
|||
|
Velocity of Propagation |
82% |
|||
|
Sweep Testing |
3.0 GHz |
|||
|
Structural Return Loss 5 — 1000MHz |
20 dB Minimum |
|||
|
Overall Jacket |
||||
|
CAT6 |
||||
|
Material |
PVC – Polyvinyl Chloride |
|||
|
Jacket Thickness |
0.023” Nominal |
|||
|
Outer Diameter (±0.1”) |
.244” |
|||
|
Ripcord |
Yes |
|||
|
Color |
Blue, Grey |
|||
|
RG6QSC |
||||
|
Material |
PVC – Polyvinyl Chloride |
|||
|
Jacket Thickness |
0.023” Nominal |
|||
|
Outer Diameter (±0.1”) |
.29” |
|||
|
Color |
Black, White |
|||
|
Overall Jacket |
||||
|
Outer Diameter |
.71 |
|||
|
Color |
Violet |
|||
|
Applicable Standards |
||||
|
Agency Listings |
UL CMR or MP CSA FT4 |
|||
|
EU RoHS Compliant (Y/N) |
Yes |
|||
|
Put-Ups and Colors |
||||
|
Stock Code |
Description |
Jacket Color |
Put-Up |
|
|
TRIBC62V2-VT05S |
2 CAT6 + 2 RG6QSC Cable Spool |
Violet |
500 ft |
|